Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
n Output data – TBEN-S2-8DXP [}53]
control word + 6 words
Word no. Bit no.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Control
0x0000
OUT
0x0001 - - - - - - - - DX7
C3P2
DX6
C3P4
DX5
C2P2
DX4
C2P4
DX3
C1P2
DX2
C1P4
DX1
C0P2
DX0
C0P4
Latch
reset
0x0002 - - - - - - - - DX7 DX6 DX5 DX4 DX3 DX2 DX1 DX0
CNT
reset
0x0003 - - - - - - - - - - - - - - - CNT
reset
PWM Ch7
0x0004 - - - - - - - - Duty Cycle
PWM Ch7
0x0005 - - - - - - - - Duty Cycle
VAUX Control
0x0006 - - - - - - - - - - - - VAUX
1 P1
C3
VAUX
1 P1
C2
VAUX
1 P1
C1
VAUX
1 P1
C0

Table of Contents