EasyManua.ls Logo

turck TBEN-S2 - Page 155

turck TBEN-S2
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V04.00 | 2021/05
155
Class 158 (0x9E) – Ext. Function Digital
This class data and parameters for the extended digital functions.
Applies to:
n TBEN-S1-8DIP
n TBEN-S1-8DIP-D
n TBEN-S1-4DIP-4DOP
n TBEN-S1-4DXP
n TBEN-S1-8DXP
n TBEN-S2-8DIP
n TBEN-S2-8DXP
Attribute no. Designation Get/
set
Type Meaning
Dec. Hex.
Parameters
1 0x01 Extended digital function
CNT
G/S USINT 0: deactivated
1: Input filter and pulse stretch
2 0x02 Input filter G/S USINT 0: 0.2ms
1: 3ms
3 0x03 Pulse stretching input
(*10ms)
G/S USINT
Class 159 (0x9F) – Ext. Function Digital
This class data and parameters for the extended digital functions.
Applies to:
n TBEN-S1-8DOP
n TBEN-S1-4DIP-4DOP
Attribute no. Designation Get/Set Type Meaning
Dec. Hex.
Parameters
1 0x01 Extended digital function PWM G/S USINT 0: deactivated
1: reserved
2: PWM output
2 0x02 Overcurrent PWM output G USINT 0: -
1: active
3 0x03 Overcurrent PWM output G USINT 0: -
1: active
4 0x04 Duty Cycle G USINT