TVL 351
ISSUE 15
Code-011 CONTROL SGL Engineers Event Set.
Engineers Event Set has been selected within the options menu by the user.
[Information]
Code-012 CONTROL DBL Car Delayed - Calls Transferred / Car Available for Calls.
Landing calls have been transferred (in group system) or cancelled because the car was delayed. Check for motion
or door related faults. Can be caused by passengers delaying the lift from starting its journey
[Breakdown]
Code-013 MOTION SGL Bottom Floor Reset.
Bottom Floor Reset has occurred - ignore if diving. On arrival at the bottom terminal floor, the lift has reset its lift
position as it does not correspond with that of the bottom floor, indicating that the lift was out of step. It is important
that the stepping signal is encountered before the terminal reset signal to avoid false events being recorded.
[Fault]
Code-014 DRIVE DBL Multi Start Fail / Multi Start OK.
More than 3 accumulated start fails have occurred, all car calls will be cancelled, hall calls released, the 'LSI'
indicator cancelled, and the event recorded. The lift doors will park open and will only close again if a car or a hall
call is operated. If another code 014 is again generated, following a further three unsuccessful attempts to start, the
doors will again park open, but will only respond to car calls.
[Breakdown]
Code-015 DOORS SGL Front Door Nudging.
Provided that there are calls present, limited force door closing will come into operation if the doors are held open for
over 25 seconds by safety edge or if there have been a set number of door reversals caused by the safety edge etc.
A buzzer will sound in the lift car, and the doors will close under limited force disregarding safety edge operation.
(The door open push is still effective in reversing and holding open the doors, but the doors will start closing
immediately once the door open push is released).
[Information]
Code-016 MEMORY SGL SRAM Test Failure.
The SRAM Test Function has returned an error during CPU initialise, report this error!
[Fault]
Code-017 CONTROL SGL CPU 24V Power OK.
CPU 24V power has recovered, check supply to main CPU, user data shows time the power has been absent
(50mS units).
[Fault]
Code-018 SERVICES DBL Self-Test Failure / Self-Test OK.
if enabled and after a timed period of idleness the lift will test itself by going to an adjacent floor and returning, If the
sequence of events does not occur within defined time limits, the 'LSI' is cancelled. Another attempt is made after a
further timed period of idleness for confirmation. If all is well, no further attempts will be made. If another failure
occurs the event is recorded, the doors will park open, and the lift will only try to respond to car calls. Check user
data/event log for supplementary information.
[Fault]
Code-019 CONTROL MAN Over Speed Governor Operated / Over Speed Gov. OK.
The Over Speed Governor has operated. Possible causes are lift over speed or uncontrolled movement.
[Breakdown]
Code-020 DOORS SGL Front Safety Edge Overtime.
If the lift doors are held open by continuous operation of the safety edge for more than 20 seconds, the event is
recorded. Check door for obstructions / SE operation.
[Information]
Code-021 DRIVE SGL Drive Start Fail.
Drive failed to complete start sequence within 3 seconds. The MPU has signalled for the lift to start and the lift has
not done so. After a short delay, the lift doors will re-open and the event is recorded, check drive safety.
[Fault]