ISSUE 15
Code-022 CONTROL SGL Events Archived.
The event log files on SD1 have been archived.
[Information]
Code-023 CONTROL SGL Logger Corrupt.
The software has reset the event logger because it was found to be corrupt following a system reset.
[Fault]
Code-024 CONTROL DBL Shaft Encoder Count Test Mode / Shaft Encoder Count Normal Mode.
The Shaft Encoder is using simulator count resolution values, do not let the panel leave the factory in this mode.
Move SW9-C2 to it's off position.
[Fault]
Code-025 MOTION SGL Top Floor Reset.
Top Floor Reset has been detected, Check proximity switches, shaft positioning device, Ignore if diving.
[Fault]
Code-026 SERVICES DBL Lost Car Push Feed / Car Push Feed OK.
Car push feed input is missing check fuses & connections. Lift may be in bus stop mode.
[Breakdown]
Code-027 SERVICES DBL Lost Land Push Feed / Land Push Feed OK.
Landing push feed is missing check fuses & connections. Lift may be in bus stop mode.
[Breakdown]
Code-028 MOTION DBL Reset Limit Error / Reset Limits OK.
Both reset limits are present, check wiring and inverted reset flag in parameters.
[Breakdown]
Code-029 SERVICES DBL Emergency Supply / Emergency Supply OK.
Lift is on Emergency Supply, check building mains.
[Service]
Code-030 MEMORY SGL Parameters Defaulted.
User and backup parameters have been successfully reset to their default state
[Information]
Code-031 DOORS MAN Gate Locks Bridged / Gate Locks OK.
Gate locks shorted. Check locks, safety, re-levelling, advance door opening circuits for shorts. Press reset button to
clear when checks have cleared
[Breakdown]
Code-032 MOTION SGL GL Lost Re-Level.
GL lost whilst on re-levelling, check lock circuit / skates etc.
[Fault]
Code-033 MOTION DBL LTLR Tripped / LTLR OK.
If during the slowing cycle the lift has taken an excessive time to obtain floor level the MPU will cause the direction
to be lost, thus stopping the lift. If the event is recorded 3 times the lift can only be reset by a car call. If nuisance
tripping occurs check value of LTLR timer setting.
[Fault]
Code-034 MOTION SGL Stuck Leveller.
Leveller or DZ stuck on high or medium speed, check shaft vanes etc.
[Fault]
Code-035 DRIVE DBL NERR Lost / NERR OK.
NERR input lost, could be drive error, check drive settings, encoder feedback signals, shaft encoder faults and