TVL 351
ISSUE 15
[Service]
Code-302 SHAFT ENC. DBL SE Limax3CP Fault or Error / SE Limax3CP OK.
Limax3CP Encoder Problem, The Limax3CP Safety Encoder has a fault, check Limax Safe Status screen in Check-
List for more detail.
[Fault]
Code-303 CONTROL MAN Limax3CP OC Contact Open / Limax3CP OC Contact OK.
The Limax3CP OC contact has operated. Check Limax3CP status screen for cause and clear fault before resetting
this event.
[Breakdown]
Code-304 CONTROL SGL Limax OC Short Check.
The OC contact of the Limax3CP device is potential shorted out, check safety circuit, processor will cycle OC to
check.
[Fault]
Code-305 CONTROL MAN Limax OC Bridged / Limax OC OK.
Limax OC shorted. Check limax OC circuit, safeties for shorts. Press reset button to clear when checks have
cleared.
[Breakdown]
Code-306 CONTROL MAN AROA (DZM) Stuck On / AROA (DZM) OK.
Stuck AROA (DZM) input. Door bridging circuit is not switching correctly, check AROA (DZM) input switching and
wiring.
[Breakdown]
Code-307 SERVICES DBL Intruder Alarm Overridden / Intruder Alarm Override Ended.
The Intruder Alarm has been overridden via the de-activation input IOV.
[Information]
Code-308 SERVICES SGL Intruder Detected.
Intruder detected, check interlock switches.