Do you have a question about the Tyco Kendall Kangaroo Joey and is the answer not in the manual?
Type | Enteral Feeding Pump |
---|---|
Model | Kangaroo Joey |
Battery Type | Rechargeable Lithium-Ion |
Increments | 1 mL/hr |
Accuracy | +/- 10% |
Power Source | Battery or AC Adapter |
Flow Rate Range | 1 to 400 mL/hr |
Volume Range | 1 to 3000 mL |
Alarms | Occlusion, Low Battery |
Compatibility | Kangaroo Feeding Sets |
Manufacturer | Tyco Healthcare (now part of Medtronic) |
Describes the pump's user interface features like LCD display and LED array.
Details the pump's physical design for ease of use, portability, and durability.
Outlines the pump's advanced capabilities like MISTIC, AFF system, and multiple languages.
Covers serial I/O, battery, and power cord features for serviceability.
Illustrates and labels the pump's front and rear components for identification.
States that the device sale is restricted to physicians or their representatives by US federal law.
Lists essential safety guidelines for operating the KANGAROO JOEY Enteral Feeding Pump.
Warns that the serial I/O port is for manufacturer use only and may affect safety.
Advises on patient tolerance, accuracy, feeding set reuse, and tube stretching.
Emphasizes keeping the buzzer hole clear for proper alarm recognition.
Warns about potential fire or chemical hazards from mistreated battery cells.
Explains the visual indicator for the pump being in Run mode on the display.
Details the icons representing different battery charge levels.
Describes the progress indicator for the auto-priming feature.
Explains the icon for alarm volume settings.
Describes the icon indicating stopped pump operations due to an error.
Explains the informational icon that requires no immediate action.
Indicates when the EZ Pump Mode feature is activated on the pump.
Shows the icon for an activated communication feature.
Signifies that a Volume To Be Delivered (VTBD) has been programmed.
Indicates that the Keep Tube Open feature is currently in operation.
Provides instructions and notes on connecting the pump's power cord.
Warns against pulling only the cord to detach the connector.
Details battery charging procedures and expected battery life.
Explains how to attach the pole clamp to the pump for mounting.
Provides a brief step-by-step guide to begin using the pump.
Details the procedure for correctly loading a pump set into the device.
Warns against overstretching the silicone tubing during pump set loading.
Specifies the required height for suspending the fluid bag for optimal accuracy.
Explains how to perform automatic priming for Feed-Only and Feed & Flush sets.
Describes the interactive method for priming using the hold-to-prime feature.
Guides on using the left-side buttons to set feeding parameters.
Instructs on how to initiate pump operation after programming.
Explains the methods for pausing or powering down the pump.
Discusses recommended methods for positioning the pump.
Details how the pump operates when connected to an AC power outlet.
Explains how the pump switches to battery power when AC is unavailable.
Provides instructions for turning the pump on and off.
Guides the user through selecting the interface language upon initial startup.
Explains options to retain or clear previous settings after powering up.
Detailed steps for loading the pump set, including diagrams.
Advises on keeping the pump set exterior free from liquid to prevent false alarms.
Reiteration of the fluid bag suspension height for loading.
Explains automatic and manual priming methods for the pump.
Details the auto-priming function and how to cancel it.
Guides on using the hold-to-prime options for precise priming control.
Specific instructions for priming feed-only pump sets.
Specific instructions for priming feed & flush pump sets.
Steps to follow when a feed bag needs refilling and re-priming.
Explains how to choose between different feeding modes.
Describes the EZ Pump Mode's limited functionality for continuous feeding.
Details how EZ Pump Mode interacts with other settings and its limitations.
Instructions on how to select and activate the EZ Pump Mode.
Explains what happens to EZ Pump Mode when a Feed/Flush set is used.
Describes the icon indicating EZ Pump Mode is active.
Explains the difference between continuous and intermittent feeding modes.
Guides on selecting continuous or intermittent mode using the More Options menu.
How to program feed rate and volume for continuous feeding.
Instructions for setting flush volume and interval in continuous mode.
Details on programming the time interval for flushing.
Caution regarding the high flush rate and its programming.
Information about the automatic 25 mL flush after formula delivery.
How to program bolus rate, number, volume, and interval for intermittent feeding.
Notes on how reprogramming bolus numbers affects ongoing feeding.
How to use the Bolus Max option for high-rate bolus delivery.
Instructions for setting flush volume and interval in intermittent mode.
Steps to start and operate the pump, including the RUNNING screen details.
Lists the screens from which the RUN option can be accessed.
Explains the KTO function to prevent feeding set blockages.
How to lock and unlock the pump's control screen to prevent unintended changes.
Procedures for pausing the pump operation and available options during HOLD.
How to reset the output feed totals (mL FED, BOLUSES FED, mL FLUSH).
How to access settings menus when the pump is in HOLD mode.
How to schedule a delayed resume for the pump after being held.
How to restart pump operation immediately after holding.
How to access and review the pump's feeding and flushing history.
Instructions for performing an immediate flush at any time.
Accessing additional functions like Buzzer, History, and Languages.
How to set the alarm volume for the pump.
How to set the time frame for retrieving historical feeding data.
How to change the pump's display language.
How to switch between continuous and intermittent feeding modes.
Introduction to the BioTech screen for technical information and settings.
Step-by-step guide to accessing the pump's BioTech menu.
Explains the meaning of data displayed on the BioTech screen (SN, SW, FLASH).
Overview of available options within the BioTech menu.
How to lock settings to prevent unauthorized changes and the resulting screen.
How to activate EZ Pump Mode via the BioTech Options.
Explains the self-diagnostic checks for re-certifying pump performance.
Detailed procedure for testing and verifying the pump's flow rate accuracy.
Provides general instructions and cautions for cleaning the pump.
Emphasizes disconnecting power before cleaning and ensuring dryness.
Specific instructions for cleaning the exterior of the pump housing.
Guidelines for cleaning the pump's power cord.
Detailed steps for disassembling, cleaning, and reassembling the rotor.
Information on periodic re-certification and service intervals.
Step-by-step guide for replacing the battery pack.
How the pump displays errors and activates audible/visible alarms.
Lists common conditions that result in error states and alarms.
Details the general system error, its severity, and resolution (power down).
Lists specific error numbers and their related sub-system issues.
Explains the HOLD ERROR screen and how to resume operation.
Describes the ROTOR ERROR and steps to resolve it, often involving pump set reloading.
Covers the FEED ERROR screen, usually caused by empty bags or occlusions.
Explains the FLUSH ERROR, typically due to empty bags or occlusions in the flush line.
Addresses the FLOW ERROR caused by downstream occlusions or valve issues.
Describes the PUMP SET DISLODGED error and its resolution.
Explains the BATTERY LOW screen and the need for recharging.
Information screen displayed after programmed feeding is finished.
Warning about exceeding 24 hours of pump set usage.
Explains the meaning of the pump's status LED lights (green, yellow, red).
Details the UL and CSA certifications for the medical equipment.
Classifies the device as a volumetric infusion device.
Identifies the pump's mechanism as rotary peristaltic.
Information on pump set compatibility with other models.
Specifies the range and increments for the feeding formula delivery rate.
Details the range and increments for the Volume To Be Delivered (VTBD).
Specifies the range and increments for bolus volume.
Defines the settable range for the number of boluses.
Specifies the range and increments for the time interval between boluses.
Defines the settable range for flushing solution dosage.
Specifies the range and increments for the flushing solution interval.
Details the accuracy specifications, including test conditions and water adjustments.
Specifies the nominal occlusion pressure the pump can generate.
Provides the physical height, width, and depth of the pump.
States the weight of the pump with and without the pole clamp.
Describes the materials used for the pump's coating and housing.
Details voltage, current, and power source requirements.
Information on battery life, charging, and low battery warnings.
Lists all possible alarm conditions for the KANGAROO JOEY pump.
Specifies the minimum alarm volume level at a set distance.
Defines the acceptable temperature range for pump operation.
Defines the acceptable temperature range for pump storage.
Classifies the pump's electrical protection level (Class II).
Identifies the protection type as Type BF.
Describes the pump's operational modes (continuous/intermittent).
States the pump's splash-proof rating (IPX4).
Explains the various safety and functional symbols found on the device and accessories.
Outlines the procedure for returning the pump for repair.
Provides contact details for customer service in the United States.
Provides contact details for customer service in the UK.
Provides contact details for customer service in Canada.
Warns against opening the main housing as it contains no user-serviceable parts.
Instructions for replacing the blue transparent top door of the pump.
Refers to Section VIII for detailed battery replacement instructions.
Steps for replacing the battery door, ensuring the seal is maintained.
Refers to Section IV for details on power cord attachment.
Refers to Section IV for details on pole clamp attachment.
Lists the part number for the main pump unit.
Provides the part number for the blue transparent main door.
Lists the part number for the replacement battery pack.
Provides the part number for the battery door.
Lists the part number for the power cord with A/C adapter.
Provides the part number for the pole clamp accessory.
Lists part numbers for various optional accessories.
Details the one-year warranty coverage for defects in materials and workmanship.
Lists compliance with RF and harmonic emission standards.
Details compliance with RF emission standards for different environments.
Indicates compliance with voltage fluctuation and flicker standards.
Details compliance with radiated disturbance immunity standards.
Details compliance with conducted disturbance immunity standards.
Details compliance with power frequency magnetic field immunity standards.
Details compliance with voltage dips and sags immunity standards.
Details compliance with electrical fast transient/bursts immunity standards.
Details compliance with electrostatic discharge immunity standards.
Details compliance with surge immunity standards.
Explains how AccuSystem feeding sets contribute to the pump's accuracy and quality.