done in UFactory Studio)
How to realize the protection reset function with reset button:
1. Configure "CI0" as the safeguard reset in UFactory studio. The specific
steps are as follows:
Enter "Settings" - "I/O" - "Input" - Configure CI0 as safeguard reset -
"Save".
2. If 850 needs to resume motion, connect SI0 and SI1 to GND, and