YK10-0015-DI-002-03
xiii
Table. 1 Standard accessories
Part name Specification Quantity Remarks
Oil one time portion ULVOIL R-72 1 set For the consumed amount, refer
to the specification table.
V belt 5V-1120 2 pcs -
Belt cover (Bolt for mounting) - 1 set -
Anchor bolt Pump, motor base, belt
cover
12 pcs -
Motor (with key) - 1pce Attached only when the motor is
placed an order.
Motor base (with bolt for motor
fixation)
- 1pce Attached only when the motor is
placed an order.
Motor pulley
50Hz spec. 1pce
Either of them only
60Hz spec. 1pce
Instruction manual English 1 copy
Nylon tube 1/4B 1 set For connecting oil pot
Oil pot With joint 1pce -
0.5.2 Transfer
WARNING
You have a risk of giving damage to your back as the load larger than
safety standard shall be required to transfer the product.
PMB-040C:970kg (Without Motor)
PMB-060C:1100kg (Without Motor)
Be sure to use the loading machinery (such as mobile crane) to lift up
the Pump or load it on the pallet and fix it with Jack and run the Pallet
truck for its transfer.
Never try to enter beneath the pump unit when lifted it up. Use the
accessory eyebolt to load/unload the unit.
Do not put the folk of the Fork lift or the like in the pump bottom
(exhaust outlet) to lift it.
Note to purge the oil to transfer the pump. If forced to transfer
remaining the oil, be sure to keep the pump horizontal. Do not tilt the
pump 10 degree or more while you charge the oil. The oil might run
into the casing.