YK10-0015-DI-002-03
12
2.4.3 Power Requirements
The power requirement of the mechanical booster pump varies with the intake pressure and the
performance of the backing pump.
With the standard backing pump, the motor is overloaded at an intake pressure of more than the
maximum intake pressure (Refer to the “Table. 2 Specifications”) and the pump generates a large
amount of heat, causing motor burn-out and pump seizure. Therefore, do not carry out operation at
a pressure higher than the maximum intake pressure.
The performance of the Mechanical booster pump shall largely depend on the Backing pump
performance as described above. You should be careful on selecting the type of the Backing pump.