YK15-0009-DI-002-04
1
1. For Your Safety Use
1.1 This Product Intrinsic Hazardous Nature and Safety Measures
Before operating or checking this machine, thoroughly read this paragraph, and after fully
understanding about latent danger and on how to avoid danger, perform the work.
1.1.1 ! Danger Leakage of dangerous gas and dangerous materials
Factors
Avoidance methods and measures
Leakage of poisonous and
combustible gas
Getting injured on touching
any toxic pump oil, pump,
generated material or sucked
substance at the occasion of
check or disposal.
Do not exhaust any hazardous gas such as
toxic and combustible.
When you check the Pump
, please wear
a brace that supports the toxic
substances that exhaust the Pump.
To overhaul or dispose,
ask the special agency to do the
detoxification process.
Ask the disposal agency licensed by the
administration for disposal.
1.1.2 ! Warning Transfer of heavy material
Factors
Avoidance methods and measures
Getting injured on
transferring
the Pump weight
VD30C: 58kg
VD40C: 60kg
VD60C: 90kg
VD90
C
: 1
13
kg
Only technically entitled person should
be in charge of
loading/unloading and
operating machines.
There is a risk that the Pump
might drop
or lay down when attempted
unreasonable
operation or machinery
setup was not sufficient.
You are strictly restricted from entering
beneath the Pump.

Table of Contents