Phone Parameters - Administration Nur für den internen Gebrauch
A31003-S2000-R102-16-7620 02/2016
142 Provisioning Service, Developer’s Guide
c04.fm
System
Built-in forwarding
Toggles phone-based call forwarding.
Symbolic name send-url-
symbolic-name
<index>
Text Default: NULL Used to assign a push re-
quest from the application
server to the appropriate
key. This value must be
unique for all keys in-
volved.
Available with OpenStage
V2R2.
>
To enable phone-based call forwarding, the server-based-features item must be set
to false; for further information, please see the parameter description in Section
4.4.5.1, "Configuration".
WBM Name Item name Type Values Description
Key label <n> key-label-
unicode
<index>
Unicode
text.
Max. 12
charac-
ters.
Default: Call
forward
Label for the key.
function-
key-def
<index>
Integer 64 Feature ID which defines
the function.
Available on all unshifted
FPKs and the Fixed For-
warding Key. No parame-
ters associated. This is
the default function for the
Fixed Forwarding Key,
and when set on an FPK,
allo ws it to act in t he sam e
way as the default Fixed
Forwarding Key.
WBM Name Item name Type Values Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage and is the answer not in the manual?

Unify OpenStage Specifications

General IconGeneral
DisplayGraphical LCD
ConnectivityEthernet
Supported ProtocolsSIP
Power over Ethernet802.3af (PoE), depending on the specific model
Supported CodecsG.711, G.729
SpeakerphoneYes
Headset PortYes
USB PortNo
BluetoothNo
Humidity10% to 90% non-condensing