Replacing the Doctor Blade Procedure (continued)
5. Tighten the four (4) mounting screws using a 3mm Allen key.
6. Insert the Doctor Blade Assembly into the mounting bracket.
7. Replace the Doctor Blade Spring and Guide Pin
8. Tighten the two cap screws, on each side, using a 4mm Allen key
9. Tighten the Button Head Screw, on each side, using a 5mm Allen key
10. The Doctor Blade should “Float” in the mounting bracket when pulled back
11. Install the Coating Drip Pan.
Figure - Coating Drip Pan
Coating Drip Pan
Figure - Mounting Bracket
Mounting Bracket
Doctor Blade Assembly
Figure - Mounting Bracket Assy
Button Head Screw
Guide Pin
Doctor Blade Spring
4mm Cap Screws