47 Translation of the original instruction”
1-4
5.1.4 Method to remove the platform controller emergency stop button
1.Push the red "emergency stop" button of the ground and platform controller into the OFF position.
2.Disconnect the platform controller from the control cable on the platform.
3.Remove the fasteners that secure the platform control box to the platform controller bracket.
4.Remove the fasteners that secure the bottom cover to the platform control box. Open the control box.
5.Disconnect the white line from the "emergency stop" button base.
Risk of electric shock / burn. Exposure to live circuits can result in death or serious injury.
Remove all rings, watches and other accessories.
Risk of damage to parts. Electrostatic discharge (SED) can damage printed circuit board
components. When operating on printed circuit boards, keep them in good contact with the metal parts
that are always grounded on the machine, or use ground tapes.
6.Carefully remove the "emergency stop" button base from the "emergency stop" button.
7.Carefully remove the retaining ring from the "emergency stop" button.
8.Carefully remove the "emergency stop" button from the platform control box.

Table of Contents

Other manuals for Upright X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Upright X Series and is the answer not in the manual?

Upright X Series Specifications

General IconGeneral
BrandUpright
ModelX Series
CategoryLifting Systems
LanguageEnglish

Related product manuals