67 Translation of the original instruction”
6.1 B system fault code
Code Fault Probable Reason Problem Solution
01
Internal ECU failure
ECU content error, EEPROM is
not programmed
Replace ECU
02
ECU / platform
communication failure
Control cable error or platform
control failure
Check the control cable
or platform control
03
The configuration code is
not defined
The machine configuration code
is set incorrectly
Set the configuration
code correctly
12
The on / off switch opens
when the switch is started
Up / down switch error
Check up / down the
toggle switch
18
Pothole protection switch
failure
The pothole protection switch is
wrong or there is an obstacle at
the connection
Check the pothole
switch or remove the
obstacle
19
Trip switch error
Stroke switch line fault or trip
switch line is open
Check the trip switch or
check the line
31
Pressure sensor error
The pressure sensor is not
installed or the line is faulty
Check the line or
replace the sensor
32
Angle sensor error
The angle sensor is not installed
or the line is faulty
Check the line or
replace the sensor
42
Left turn switch error
Turn left micro switch fault
Check the left turn
micro switch
43
Right turn switch error
Turn Right micro switch fault
Check the Right turn
micro switch
46
Drive confirmation switch
error
Drive confirmation switch failure
Check the travel
confirmation switch
47
The platform handle is
wrong
The handle is not centered
Correct or replace the
handle
52
Forward coil error
Coil fault or coil circuit break
Check the coil or
service line
53
Backward coil error
Coil fault or coil circuit break
Check the coil or
service line
54
Platform up coil error
Coil fault or coil circuit break
Check the coil or
service line
55
Platform down coil error
Coil fault or coil circuit break
Check the coil or
service line
56
Turn right coil error
Coil fault or coil circuit break
Check the coil or
service line
57
Turn left coil error
Coil fault or coil circuit break
Check the coil or
service line
58
Brake coil error
Coil fault or coil circuit break
Check the coil or
service line

Table of Contents

Other manuals for Upright X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Upright X Series and is the answer not in the manual?

Upright X Series Specifications

General IconGeneral
BrandUpright
ModelX Series
CategoryLifting Systems
LanguageEnglish

Related product manuals