8000026412_01 Air/flue pipe installation manual 27
55
2. Secure the extensions to the wall using the pipe
clamps.
Use one pipe clamp for each extension directly
beside the sleeve.
Upstream of each elbow, install another pipe clamp
on the extension.
Secure the 87° elbow with bird-guard grille using a
separate pipe clamp.
5.9.5.5 Routing extensions for the variable terminal
set around eaves
min. 400 mm min. 100 mm
When installing the variable terminal set around eaves, ad-
ditional M8 threaded rods are required for the pipe clamps.
The threaded rods are commercially available.
If required, install additional 45° elbows.
Install the bird-guard grille from the 87° elbow in the last
extension.
If you are using the 87° elbow, insert the seal for the
extension.