8000026412_01 Air/flue pipe installation manual 39
5.15.4 Connecting the product
1. Install the product (4) – see the installation instructions
for the product.
2. If required, replace the connector for the air/flue pipe
(3), see the installation instructions for the product.
3. Connect the connection elbow (2) to the connector for
the air/flue pipe (3).
4. Insert the sliding sleeve (5) with the sleeve as far as it
will go in the wall/roof duct (7) or the extension (6).
5. If required, install the extensions .
6. Connect the sliding sleeve to the connection elbow.
7. Install the air pipe clamp (1) for the sliding sleeve.
8.
Alternatives 1:
Condition: Wall/roof duct without extension
▶ Install the sliding sleeve. (→ Section 5.19.1)
8.
Alternatives 2:
Condition: Wall/roof duct with extension
▶ Install the extensions. (→ Section 5.19.2)
▶ Install the elbows (→ Section 5.19.3).
▶ Install the sliding sleeve. (→ Section 5.19.1)
▶ Connect all of the pipe joints with air pipe clamps.
(→ Section 5.19.5)
5.16 Installing the vertical roof duct
5.16.1 Installation instructions
Danger!
Risk of poisoning due to escaping flue
gas and risk of material damage due to the
roof duct shearing off.
Snow and ice sliding down pitched roofs may
break off the vertical roof duct where it exits
the roof.
▶ In regions where heavy snow
falls/extensive ice formation can be ex-
pected, install the vertical roof duct close
to the ridge or install a snow guard mesh
above the roof duct.
The vertical roof ducts can be shortened under the roof.
However, to ensure that the fixing bracket is secured tightly,
the lengths must still be sufficient.
▶ Shorten the flue pipe and the air pipe by the same
amount.
5.16.2 Installing the vertical roof duct – 0020223472
– 60/100 mm diameter
5.16.2.1 Assembling the vertical roof duct
Note
In its as-delivered condition, the lower pipe of the
vertical roof duct is pushed into the upper pipe.
1. Remove the clamp fitting (3) from the inside of the flue
pipe (2) (step A).
2. Separate the flue pipe (2) from the terminal piece (1)
by pulling them apart (step B).
3. Turn the terminal piece over and set it on the floor
(step C).
4. Slide the flue pipe (2) downwards onto the terminal
piece (1) until all four fastenings click into place (step
D).
5.16.2.2 Scope of delivery – 0020223472 (black, with
collar)
1 Vertical roof duct
2 Fixing bracket
3 48 mm air pipe clamp
4 Collar