7.8 Test mode
Always perform the following steps after performing
any maintenance work:
Commission the appliance in accordance with the in-
structions in the relevant operating manual.
Check the appliance for gas and water leaks.
Check the entire air/flue gas system for leaks and se-
curely fixed.
Check ignition and even flame appearance of the
burner.
Check whether the heating system and the hot water
preparation is functioning.
Complete the Benchmark gas boiler commissioning
checklist in the rear section of these instructions.
Fig. 7.13 Function check
Inspection and maintenance 7

Table of Contents

Other manuals for Vaillant ecoTEC plus 937

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus 937 and is the answer not in the manual?

Vaillant ecoTEC plus 937 Specifications

General IconGeneral
ModelecoTEC plus 937
CategoryBoiler
TypeCombination
Output37 kW
Dimensions720x440x338 mm
MountingWall-mounted
ERP Efficiency RatingA
Fuel TypeNatural Gas
Flow Rate15.2 l/min
Hot Water Flow Rate15.2 l/min at 35°C temperature rise
Gas TypeNatural Gas
Warranty5 years
Efficiency94%
DHW Output4.0 - 37.0 kW