Chapter 4 _______________________________________________________________ Installation 
 
VAISALA _______________________________________________________________________ 55 
Table 10  Connecting RS485 Cable 2m (228259SP) and RS485 
Cable 10m (228260SP) 
Power Supply  Wire Colors   Pin 
Operating Power Supply  White   1 
Operating Power Supply Ground  Gray-Pink  11 
Heater Power Supply  Gray, Green, Pink  5, 6 
Heater Power Supply Ground  Blue, Black, Red, Yellow  7, 8 
Enclosure Ground  Shield  Shield 
COM2   
RS485, B  Brown  3,4 
RS485, A  Red-Blue  14, 15 
Communications Ground  Violet  10 
 
Connector Signals 
Figure 25 on page 56 and Table 11on page 56 describe the pin-out of the 
17-pin M23 connector as seen from the outside. The serial output type of 
COM2 depends on the sensor configuration. Analog outputs are always 
available from the connector.