EasyManua.ls Logo

Vaisala WMT703 - Table 21 Monitoring Items for Data Messages

Vaisala WMT703
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 ____________________________________________________ Configuration commands
VAISALA _______________________________________________________________________ 85
Table 21 Monitoring Items for Data Messages
Item Description
\er Status code. The code is a decimal number. Each bit
corresponds to a status flag. For a list of the bits, see section
Status Flags on page 86.
\fb 0 = No error
1 = Blocked sensor
\fh 0 = No error
1 = Heater failure. Incorrect heater resistance.
\fs 0 = No error
1 = Wind speed exceeds operating limits
2 = Sonic temperature exceeds operating limits
3 = Wind speed and sonic temperature exceed operating limits
\ft This value indicates temperature sensor failures when converted
to binary format:
Bit 0 = Temperature sensor 1 failure
Bit 1 = Temperature sensor 2 failure
Bit 2 = Temperature sensor 3 failure
\fv 0 = No error
1 = Supply voltage (Vh or Vi) too high
2 = Supply voltage (Vh or Vi) too low
\pa Average heating power
\ra Heater resistance
\ta Transducer temperature
\ti Internal temperature
\vh Heater voltage
\vi Supply voltage
Example 1:
In this example a new data message with identification number 1 is
defined. The items included in the message are average wind speed,
average wind direction, and supply voltage.
S msg1,$\ws,\wd,\vi\cr\lf
When the above message is polled, WMT700 sends the following data if
the average wind speed is 5 m/s, the average wind direction is 128
degrees, and the supply voltage is 23.4:
$005.00,128,23.4<CR><LF>