Chapter 6 ____________________________________________________ Configuration commands
VAISALA _______________________________________________________________________ 79
ERRORS
The response is the following:
a,b,c,d,e,f
where
a = Number of events since latest reset.
b = The code for the first event since latest reset.
c = The code for the most recent event.
d = Number of errors since latest reset.
e = The code for the first error since latest reset.
f = The code for the most recent error.
Example:
1,3,3,10,13,13
Interpretation of the example message:
- Number of events since latest reset: 1
- The code for the first event since latest reset: 3
- The code for the most recent event: 3
- Number of errors since latest reset: 10
- The code for the first error since latest reset: 13
- The code for the most recent error: 13
If no errors or events have occurred yet, the response is the following:
0,0,0,0,0,0
CLEARERR — Reset Error Codes and
Counts
This command resets the error counters of WMT700.
CLEARERR

Table of Contents