Appendix D ___________________________________________________Configuration Parameters 
 
VAISALA ______________________________________________________________________ 129 
APPENDIX D 
CONFIGURATION PARAMETERS 
This appendix lists WMT700 Configuration parameters. 
Parameter 
Name 
Default 
Value 
Allowed Values  Units  Description 
address  A  String with a 
maximum of 40 
characters. 
  Address for WMT700. Note that the SDI-
12, ASCII, NMEA Extended, ASOS and 
MES12 profiles use the first character 
only.  
SDI-12 only uses digits 1 … 9. 
aoErrValue  1000  0 … 32000  V, mA, 
Hz 
Value for analog output if wind 
measurement fails. 
aout1_g 
aout2_g 
1  0 ... 100    Gain for AOUT1 (wind speed) and  
AOUT2 (wind direction). 
aout1_o 
aout2_o 
0  -10000 … 10000    Offset for AOUT1 and AOUT2. 
 
aout1maxv 
aout2maxv 
 
32000 0…32000  V, A, 
Hz 
Analog output maximum value for 
AOUT1 and AOUT2. The output is fixed 
to this value. The unit depends on analog 
output mode.  
aout1minv 
aout2minv 
 
0 0…32000  V, A, 
Hz 
Analog output minimum value for AOUT1 
and AOUT2. The output is fixed to this 
value. The unit depends on the analog 
output mode. 
aout1mode  3  0 = current 
1 = voltage 
2 = frequency 
3 = disabled 
  Analog output mode for AOUT1. 
aout2mode  7  4 = current 
5 = voltage 
6 = potentiometer 
7 = disabled 
  Analog output mode for AOUT2. 
 
autoInt  1  0.25 ... 1000  
 
Resolution: 0.25 
s  Automatic message interval in seconds. 
This parameter affects both serial 
communication and analog output. 
Do not select a message interval that is 
shorter than the time it takes to send a 
data message. 
autoPort  1  1 = COM1 port 
2 = COM2 port 
  Serial port to which WMT700 sends 
automatic data messages.  
autoSend  0  0 = automatic 
messages disabled 
1 … 99 
  Automatic data message number. 
Selects the data message format for 
automatic messages.