USER'S GUIDE____________________________________________________________________
96 __________________________________________________________________ M211095EN-C
WMT700 Data Message 23
WMT700 Data Message 23 reports wind measurement and self-
diagnostics data in the format described below:
$\ws,\wd,\wp,\wm,\Ts,\vh,\vi,\ta,\er\cr\lf
where
$ = Fixed text
\ws = Wind speed, average
\wd = Wind direction, average
\wp = Wind speed, peak
\wm = Wind speed maximum
\Ts = Sonic temperature
\vh = Heater voltage
\vi = Supply voltage
\ta = Transducer temperature
\er = Status code. The code is a decimal number. Each bit
corresponds to a status flag. For a list of the bits, see
section Status Flags on page 86.
\cr = CR (carriage return)
\lf = LF (line feed)
Example:
$03.21,75.83,03.34,03.15,22.37,12.2,23.5,20.0,32<cr><lf>
Interpretation of the example message:
- Wind speed, average: 3.21 m/s
- Wind direction, average: 75.83 °
- Wind speed peak: 3.34 m/s
- Wind speed maximum: 3.15 m/s
- Sonic temperature: 22.37 °C
- Heater voltage: 12.2 V
- Supply voltage: 23.5 V
- Transducer temperature: 20.0 °C
- Status code: 32 which corresponds to status bit 5