Compa II series Options
07.15 Operating manual 67
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'stamp on' is
selected. The time period can be adjusted while the stamp is kept in
the labelling position for applying the label onto the goods.
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'blow on' is
selected. The time period can be adjusted, while the blowing air is
switched on for transferring the label onto product.
Value range: 0 … 2500 ms
Step size: 10 ms
Default: 100 ms
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'blow on' and
mode 'apply-print' are selected.
Waiting position up:
In cyclic mode the pad with the printed label waits in the labelling
position near the dispense edge of printer for the external start signal.
Waiting position down:
In cyclic mode the printed label is transported to the labelling position
at the end of a cycle.
So the next cycle begin with blowing up the label.
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'blow on' is
selected. The time period can be adjusted while the roll on pad is
stopped in labelling position.
Value range: 0 … 5000 ms
Step size: 10 ms
Default: 0 ms
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'blow on' and 'roll
on' are selected. The time period can be adjusted for the cleaning
period of pad after application procedure.
Value range: 0 … 2500 ms
Step size: 10 ms
Default: 100 ms
Press key
to arrive the next parameter.
Moving up and down of pad.
If the pad does not reach the corresponding final position within the
set time, then an error message appears ('final position above' at
moving up and/or 'final position below' at moving down).
Value range: 0 … 5000 ms
Step size: 10 ms
Default: 0 ms
Pressure time
Blow time
Waiting position
Roll on time
Cleaning time
Stroke timeout