CAP. 6 - TECHNICAL FEATURES 30 / 74 ENGLISH
ClimFill Maxi
CAP. 6 - TECHNICAL FEATURES
Vessels for R134a fluids
Capacity 40 l
Maximum operating pressure (PS) 20 bar
PED category (Dir.97/23/EC) II
Weight of gas content Scale
Safety valve
Type Nuova General Instruments
D7/S
Calibration pressure 20 bar
PED category (Dir.97/23/EC) IV
Containers for oil and detection dye
Recovered oil container capacity 250 ml
New PAG oil hermetic container capacity 250 ml, with OIL CARE valve
UV detection dye hermetic container capacity 250 ml, with OIL CARE valve
Pneumatic circuit
Vacuum pump flow rate 167 l/min in single stage
Vacuum level 0.05 mbar
Vacuum pump oil life 60h – extensible to max 1000 h with Pump
Monitoring System procedure
Refrigerant recovery compressor cubic capacity 14 cc
Dryer filter life Replacement every year since
installation date
Non-condensable gas vent automatic
HP and LP taps automatic
Safety pressure switch
Type 13/18bar ¼ SAE
Trip pressure 18 bar
PED category (Dir.97/23/EC) IV
Pneumatic fittings
Net length of external HP and LP hoses 4,5 m
Digital HP and LP pressure gauges 32 bar, class I sensors
Vessel pressure gauge 32 bar, class I sensor
Interface and software
Display Graphic 4,3” WideScreen 480x272, 65536
colours
Keypad Touch screen
Updating RS232 (accessible externally via cable or
ClimFill
®
Solution accessory)
Printer Thermal, 24 columns
Functions
R-134a recovery, exhausted oil recovery, vacuum
pump, recharge, oil and detection dye injection
Automatic and manual
Recycling mode Single or “Tank refrigerant internal
recycling”
Recovered oil measurement Automatic weighing, accuracy ±10 g
New oil automatic injection Automatic with scales
UV detection dye automatic injection Timed
Flushing “Regular” function (standard)