ENGLISH 37 / 74 CAP. 8 - COMMISSIONING
ClimFill Maxi
The LP gauge indicates the pressure inside the external tank.
After some minutes the product will automatically end the function.
At the end, the weight of the charged refrigerant will be displayed.
8.4 NEW OIL BOTTLE FILLING
The new oil container is on the left, looking at the product from the front.
To fill it, it has to be extracted from its housing by means of the quick coupler on the top
of the bottle; slightly press downward the coupler ring nut to extract it.
Fill the bottle paying special attention to the “oil care” valve.
This valve is made of a silicon polymer membrane; it compensates pressure variations
within the bottle and stops humid air infeed inside, thus preserving the new oil inside.
After filling, close the bottle and place it back in its seat.