ENGLISH 53 / 74 CAP. 13 - MAINTENANCE
ClimFill Maxi
• trained in maintenance in line with the instructions given in the use and
maintenance manual.
INTERVENTIONS ON SERVICE STATION COMPONENTS WHICH ARE NOT
MENTIONED IN THE FOLLOWING PARAGRAPHS ARE PROHIBITED.
MAKE SURE THE EQUIPMENT IS UNPLUGGED FROM THE POWER MAINS
BEFORE OPENING.
13.1 SELF LEAK TEST
In the main menu, select MAINTENANCE and press “SELF LEAK TEST”.
A leak test is carried out on the internal components of ClimFill
®
Maxi.
This phase includes:
• Hoses emptying
• Vacuum test
This test allows to check the tightness of the internal circuits of the ClimFill
®
equipment from
the solenoid valve allowing the fluid outflow from the internal vessel to the manifold
(metallic component housing the check solenoid valves) to the compressor infeed,
including the dryer filter leak test.
In case of failed leak test, it is necessary to check the charge hoses conditions and the
quick couplers tightness, repair if needed and then repeat the test (for the touchscreen
use, see chap. 5.8).
13.2 PUMP MONITORING SYSTEM SPECIAL FUNCTION -
VACUUM PUMP OIL CHANGE
The equipment is equipped with a special function named PUMP MONITORING SYSTEM
that enables to optimize the use of vacuum pump oil, avoiding replacement every 60
hours of operation.
PUMP MONITORING SYSTEM is the special function allowing to extend up to 1000 hours the
life of the pump oil used in the station.
PUMP MONITORING SYSTEM function performance is suggested at the end of 60-hour
operation intervals of the vacuum pump and can be manually activated in the
MAINTENANCE menu.
PUMP MONITORING SYSTEM procedure has to be started only after checking and, if
necessary, topping up the pump oil level and lasts 1 hour: during this time the equipment
cannot be used.
During the procedure, oil is automatically purified from the gaseous polluting residues
absorbed during the emptying operations of vehicles air conditioning systems.
At the end of the procedure, the vacuum pump performance check is carried out and a
result is provided to the operator.
In case of negative result you have to replace the vacuum pump oil.