CAP. 13 - MAINTENANCE 54 / 74 ENGLISH
ClimFill Maxi
After 1000 hours of vacuum pump operation since the last oil change, the PUMP
MONITORING SYSTEM procedure cannot be activated anymore and you have to replace
the oil according to the following instructions.
Required equipment:
Medium crosshead screwdriver
Hexagon wrench (6 mm)
funnel
Exhausted oil tank
For replacement (for the picture see the next page) follow the instructions indicated
below:
1. Disconnect the equipment from the mains.
2. Remove bolts (6) securing the front door and remove it.
3. Place a container under the pump oil drain hole. Open the upper plug and then
the lower plug to drain the exhausted oil contained within the vacuum pump.
4. Once the pump has been emptied, rescrew the bottom plug.
5. Fill the pump with new oil via the filler cap; use a funnel if necessary. Bring new oil
level halfway through the sight glass.
6. Once the pump is full, close the top cap.
Now switch the unit on and in the MAINTENANCE menu select PUMP OIL REPLACEMENT:
press RESET to reset the counter. (For the touchscreen use, see chap. 5.8)
When ClimFill
®
Maxi is switched on, if the 60-hour period is coming to an end (9 hours
before, that is 15 % of the period), a black bar is displayed as in the picture below.
Upon the 60-hour period expiry, the PUMP MONITORING SYSTEM function will be
proposed to the operator or the need to replace the oil.
OIL INSPECTION
WINDOWS
UPPER
FILLING
LOWER
DRAIN
PLUG