Put the tap (
code 10222032
) and screw it (in clockwise direction) to the disc.
The cylinder cover is now fully assembled and positioned.
13.4.2 CLEANING OF CYLINDER (ICE CREAM )
Cleaning process:
make sure that the mixture treating control panel is in STOP state;
make sure that the ejection opening is well closed;
open the cylinder cover and pour approximately 10 cm of water into the
cylinder;
close the cylinder cover;
press the MIXING key;
observe the machine’s operation for 10 seconds at the most; (the
appliance may continue to run without ice cream mixture 10
seconds at the most; extended operation of the appliance without
mixture is not allowed!);
press the STOP / RESET key;
turn off the SAFETY SWITCH and the MAIN SWITCH;
place a suitable container under the ejection opening and empty the
water out of the cylinder (if necessary the procedure must be repeated);
Open the batch feeder cover.