Run 9
________________________________________________________________________________________
_______________________________________
9-66
9.3.6 Advanced Controls: Panel Shapes
970 Enable Concave Sensor Turning this on enables the concave sensor which is
required to be activated for tight concave (internals
corners) less than 70mm. Refer section 9.4.3
971 Retract on Bump Bar Turning this on makes the bump bar retract when
touched. It will remain retracted until the Hold Count
Bump Bar (973) counts out. Refer 9.4.2
972 Enable Special Sequence Turning this on enables special sequences.
Refer section 9.4.1
973 Hold count bump bar Distance after bump bar is released before speed, bias
and roller pressure return to standard.
975 Feed distance (cm) Display of feed distance in cm from start of edgeband.
976 Curve convex Display of convex sensor status. Red means sensor is
Sensing the panel. Grey means it has dropped off and
therefore had detected an external corner. Refer 9.4
977 Bump Bar Display of bump bar status. Red means bar is at rest.
Grey means the bump bar has been activated. Refer 9.4
978 Bump Switch Display of bump switch status. Read means switch has
been activated. Refer 9.4
979– 983 Special Sequence Refer section 9.4.4 Special Sequence use and setup.
976
978
984
979