D051-301, Rev. V
Installation, Operation, & Service
Maxxum
®
Big-Flo
®
6” Submersible Pump
Red Jacket
®
Quick-Set
®
Submersible Pump

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Veeder-Root Red Jacket Maxxum Big-Flo Quick-Set Series and is the answer not in the manual?

Veeder-Root Red Jacket Maxxum Big-Flo Quick-Set Series Specifications

General IconGeneral
BrandVeeder-Root
ModelRed Jacket Maxxum Big-Flo Quick-Set Series
CategoryWater Pump
LanguageEnglish

Summary

Notice

Damage Goods/Lost Equipment

Procedure for reporting and handling damaged or lost equipment during shipment.

Veeder-Root's Preferred Carrier

Instructions for filing claims with Veeder-Root's designated shipping carrier.

Customer's Preferred Carrier

Process for customers to file claims when using their own shipping carrier.

Return Shipping

Procedure for returning products, requiring a Return Goods Authorization (RGA) number.

Introduction

Safety Precautions

Alerts to potential hazards like explosive fuels, flammability, and electrical shock.

Warnings and Instructions

Provides critical safety information and guidance for installation, inspection, and maintenance.

Hazardous Materials

Details potential health hazards from materials and advises on safe handling and cleanup.

Requirements For Use

Specifies conditions and regulations for the product's intended application and environment.

Operating Precautions

Advises on safe practices during operation, such as avoiding open flames and mobile devices.

Fuel Compatibilities

Lists fuels and blends that the pumps are UL listed to operate with.

Installation

Installation Safety Notices

Emphasizes safety considerations for installers, including compliance with codes and leak detection.

Follow These Directions Carefully

Key points to verify before commencing the installation process.

Installing The Pumping Unit

Step-by-step guidance for physically mounting and securing the pump assembly.

Attaching the Expansion Relief Vent Line

Instructions for connecting the vent line to the pump manifold.

Wiring the Conduit Box

Detailed steps for making electrical connections within the pump's conduit box.

Wiring Instructions - Single Phase Pumps

Specific wiring configurations for 208-230V single-phase pump installations.

Wiring Instructions - Three-Phase Pumps

Guidelines for wiring 208-230, 380/415, or 575V three-phase pump installations.

Motor Rotation

Procedure to verify and correct the motor's rotational direction for optimal performance.

Starting and Completing Installation

Steps to ensure the system is properly purged and ready for operation after installation.

Floating Suction Installation

Guidance on installing the floating suction adapter for product intake.

Installing Big Flo Diaphragm Valve

Instructions for installing the Big-Flo diaphragm valve for leak detection.

Attaching Siphon & Vacuum Lines

Procedure for connecting siphon and vacuum lines to the pump assembly.

Installing Two Pumps for Tandem Operation

Steps for manifolding two pumps to increase flow rate or provide backup.

Testing the Installation

Testing the Piping

Method for pressure testing the installed piping system for leaks.

Testing the Tank

Procedure for performing pressure tests on the tank and associated lines.

Purging the System

Steps to remove air from the system and ensure proper product flow through dispensers.

Adjusting Pressurstat Line Relief Pressure

Instructions for setting the desired line pressure after the pump stops.

Service and Repair

Removing the Extracta Assembly

Procedure for safely detaching the extracta assembly from the pump.

Removing Plug-in Type Pump - Motor Assembly

Steps for detaching and replacing the plug-in pump motor unit.

Installing the Extracta Assembly

Guidance on reassembling the extracta assembly onto the pump.

Replacing the Check Valve Assembly

Detailed steps for removing and reinstalling the pump's check valve.

Repairing Check Valve Lock-down Screw and Seals

Instructions for maintaining and replacing components of the check valve lock-down mechanism.

Parts

Packer Manifold Assembly - Side View

Diagram and part identification for the side view of the packer manifold assembly.

Packer Manifold Assembly - Top View

Diagram and part identification for the top view of the packer manifold assembly.

Yoke Assembly

Diagram and part identification for the pump's yoke assembly.

Motor Control Box 2HP Pumps

Diagram and part list for the 2HP single-phase motor control box.

Replacement Pump Motors

List of replacement pump motors with specifications like HP, voltage, and phase.

Magnetic Contactor 3-Phase Pumps

Selection guide for magnetic contactors based on pump HP and voltage.

Appendix A: ATEX Safety Instructions

EC Declaration of Conformity

NYC Fire Dept. Conditions of Approval

ANZEX Conditions of Certification