Manual No: 577014-335 Revision: B
Installation, Setup and Troubleshooting Manual
VaporTEK - VTEK3 Controller Board

Table of Contents

Other manuals for Veeder-Root VaporTEK

Questions and Answers

  • Y
    ykelleyAug 12, 2025
    Why does my Veeder-Root Test Equipment pump fail to start?
    • C
      cacostaAug 13, 2025
      If the Veeder-Root Test Equipment pump fails to start, several issues could be the cause. First, check if the electrical system fuse is blown or the circuit breaker has tripped; if so, replace the fuse or reset the breaker. Also, verify that the VaporTEK Controller is receiving power by checking if the power circuit breaker is on and confirming the input voltage rating. If the F1 fuse on the VaporTEK Controller is blown, the controller may need replacement.
  • A
    Andrea HuntAug 16, 2025
    What to do if Veeder-Root Test Equipment pump won't start?
    • K
      Kimberly HarveyAug 16, 2025
      If your Veeder-Root Test Equipment pump won't start, begin by checking the power to the VaporTEK Interface. Ensure the V4 light is illuminated; if not, consult the wire schematic in Figure 12, restore input power, and verify the input voltage rating. Also, inspect the F1 fuse (T250mA) on the VaporTEK Interface and replace it if blown. The fuse should be rated for 250V/250mA.
  • A
    Amanda GarrettAug 20, 2025
    How to troubleshoot Veeder-Root Test Equipment when pump fails to start?
    • V
      Vanessa HigginsAug 20, 2025
      If the Veeder-Root Test Equipment pump is not starting, first check the cable connections between the VaporTEK Pump and VaporTEK Controller to ensure they are correctly wired according to the equipment wiring schematics. If the wiring is incorrect, correct it. If the VaporTEK Pump and Controller were wired incorrectly, consider replacing both. Also, verify the wiring connection of the VaporTEK Interface inputs per the appropriate schematic.
  • C
    Cynthia CastilloAug 25, 2025
    What causes Veeder-Root Test Equipment pump not to start and how to fix it?
    • M
      Melanie ChavezAug 25, 2025
      If the Veeder-Root Test Equipment pump is not starting, ensure that the VaporTEK controller or interface is not defective by replacing it. Also, check for a missing or incorrectly connected RJ12 cable between the VaporTEK interface and controller, referring to the equipment wiring schematic to connect it correctly. Also, verify if LEDs V12 and V13 are flashing simultaneously; if not, the RJ12 cable may be defective and should be replaced.
  • R
    rodriguezrobertAug 27, 2025
    How to fix Veeder-Root Test Equipment when pump won't start?
    • S
      Stephanie WilsonAug 27, 2025
      If the Veeder-Root Test Equipment pump is not starting, check for a blocked outlet or discharge line and clean it. If the flame arrestors are clogged, replace them. Also, verify the wiring and hook signal input voltage rating to ensure there is a hook signal input. Additionally, inspect the pulse input wiring on the VaporTEK Interface and verify the input LEDs, referring to the VaporTEK Interface LED section.
  • C
    cwestAug 31, 2025
    What if Veeder-Root Test Equipment pump doesn't start?
    • G
      gailmarshallAug 31, 2025
      If the Veeder-Root Test Equipment pump is not starting, it might be due to the VaporTEK Interface inputs being configured incorrectly; configure the inputs correctly, referring to the VaporTEK Interface setup. Also, check if the flow rate is below 6 lpm and increase the fuel flow rate beyond this threshold. Finally, ensure that the pot setting is not too low and increase it if necessary.
  • Q
    qpatelSep 4, 2025
    Why Veeder-Root Test Equipment pump does not start?
    • S
      Susan CarlsonSep 4, 2025
      If the Veeder-Root Test Equipment pump is not starting, and a low voltage hook signal is wired directly to the VaporTEK Controller, note that the VaporTEK Controller requires high voltage hook signals (110-220 VAC). Add a VaporTEK Interface or Switch Relays as discussed in “VaporTEK Pump Configuration” on page 17. Also, if the temperature in the hydraulics area of the dispenser is below the VaporTEK pump’s rating, creating too much starting torque friction, install an appropriate heater as defined by the dispenser manufacturer.
  • L
    Laura SotoSep 7, 2025
    What to do if Veeder-Root Test Equipment pump thermal protector trips?
    • K
      Katherine YoungSep 7, 2025
      If your Veeder-Root Test Equipment pump thermal protector trips, it could be due to the ambient temperature being above the rated temperature of the product. Verify proper ventilation for the VaporTEK Pump. Wait a couple of minutes before restarting the pump.

Summary

General Safety Precautions

Fire and Electrical Hazards

Details risks from explosive/flammable fuels and high voltage electricity.

Critical Safety Warnings

High-Risk Installation Hazards

Warns about severe risks associated with installation in combustible environments.

Precautions for Safe Operation

Essential steps to ensure safety during installation and operation.

VaporTEK Pump Certifications and Markings

Hazardous Area Installation Instructions

Specific guidelines for installing the pump in potentially explosive atmospheres.

VaporTEK Pump Characteristics

Key Pump Operating Features

Describes how the pump is driven and its integrated safety features.

VaporTEK Pump Dimensions and Specifications

Technical Pump Specifications

Lists performance and operational parameters of the VaporTEK Pump.

VaporTEK Controller Overview

VaporTEK-3 Controller Board Connections

Diagram illustrating electrical connections to the controller board.

VaporTEK Pump Configuration Options

Configuration Types and Operational Modes

Table describing configurations, input types, modes, and methods of operation.

VaporTEK Pump Installation

General Pump Installation Steps

Step-by-step guide for physically installing the VaporTEK Pump.

VaporTEK Pump Installation Orientations

Acceptable Pump Mounting Positions

Illustrates correct and incorrect ways to orient the pump during installation.

VaporTEK-3 Controller and Pulse Interface Installation

VaporTEK-3 Controller Board Installation

Detailed procedure for mounting the VaporTEK-3 Controller board.

VaporTEK Pulse Interface Adapter Board Installation

Mounting and Connecting the Pulse Interface Board

Steps for mounting and wiring the Pulse Interface Adapter Board.

Retrofit Installation of VaporTEK-3 Controller Board

Retrofit Procedures

VaporTEK-3 Controller Board Replacement

Steps for replacing only the VaporTEK-3 Controller board.

VaporTEK Controller and Pump Replacement

Steps for replacing both the controller board and the VaporTEK pump.

VaporTEK System Wiring Schematics

General VaporTEK Wiring Instructions

Provides an overview and instructions for wiring the VaporTEK system.

High Voltage Hook Signal Wiring

VaporTEK High Voltage Hook Signal Diagram

Illustrates the wiring for high voltage hook signals to the controller.

Liquid Pulse Signal Input Wiring

VaporTEK Liquid Pulse Signal Diagram

Shows the wiring for liquid pulse signal inputs to the controller.

Liquid Pulse Signal Input and Monitoring Wiring

VaporTEK Pulse Input and Monitoring Diagram

Wiring diagram for pulse inputs and monitoring via ribbon cable.

Serial Connection and Monitoring Wiring

Low Voltage Hook Signal Wiring

VaporTEK Communication Setup via Laptop

Establishing Laptop Connection to Controller

Steps to connect a laptop to the VaporTEK-3 Controller using a USB adapter.

HyperTerminal Connection Configuration

VaporTEK Controller Configuration Settings

Pulse Ratio and Re-regulation Settings

VaporTEK Calibration Procedures

Manual Calibration with Speed Setup

Calibrating the system by adjusting motor speeds based on HV signals.

Dry Calibration - A;L Adjustment

Gas Meter Calibration

Gas Meter Calibration Factor Matching

Pulse Rate Setup with FB1 Terminal

Pulse Rate Setup via FB1 Terminal

Auto-Calibration using FB1 Terminal

Initiating and Performing Auto-Calibration

Steps to start and execute the automatic calibration process.

Auto-Calibration Process Steps

Setting the A;L Ratio Rate

Adjusting the A/L Ratio during the auto-calibration process.

Simulation with FB1 Terminal

Executing Simulation Steps

Step-by-step guide to run simulation tests on the system.

Simulation Setup and Selection

Interpreting Simulation Results

VaporTEK Pump Troubleshooting Guide

Common Troubleshooting Scenarios

Guidance for resolving typical issues encountered with the VaporTEK pump.

Troubleshooting with Simulation Data