Communication Setup - VaporTEK Interface Setup with Laptop
42
16. Pulse – Ratio: Press ‘7
This sub items allows a modification of Pulse Ratio. The pulse ratio defines the fuel flow rate which has to
match the dispenser flow rate. Refer to the dispenser manufacturer’s manual to input the correct pulse ratio.
17. Re-regulation factors: Press ‘8
Use item 8 to review the re-regulation factors those will be controlled by the intelligent re-regulation of
monitoring. The permitted re-regulation range is (85 – 125)%. A factor value of 100 represents 100%.
New Connection Hyperterminal
File Edit View Call Transfer Help
Print echoCaptureNUMCAPSSCROLL9600-8-N-1Auto detectConnected 0:02:44
7. Pulse - Ratio
------------------
Pulse rate [Imp/l] = 100
Pulse Prescaler = 1
Pulse Prescaler x Pulse rate = 100 pulse/1
do you want to change these [Y/N]? Y
Input Pulse Ratio [pulse/l] (10 - 250):136
New Pulse Prescaler(1...10):1
Data have been written successfully
Pulse rate [Imp/l] = 136
Pulse Prescaler = 1
Pulse Prescaler x Pulse rate = 136 pulse/1
New Connection Hyperterminal
File Edit View Call Transfer Help
Print echoCaptureNUMCAPSSCROLL9600-8-N-1Auto detectConnected 0:02:44
8. Show Reregulation factors
----------------------------
side A = 100
side B = 100
do you want to change these [Y/N]? N

Table of Contents

Other manuals for Veeder-Root VaporTEK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Veeder-Root VaporTEK and is the answer not in the manual?

Veeder-Root VaporTEK Specifications

General IconGeneral
BrandVeeder-Root
ModelVaporTEK
CategoryWater Pump
LanguageEnglish

Related product manuals