Communication Setup - VaporTEK Interface Setup with Laptop
39
12. Set Factory Defaults: Press ‘3
This function sets all configuration parameter into default conditions.
M1 and M2 H/V-Inputs are set default 1000 RPM.
The Pulse Ratio is set to 136p/l.
The A/L - Ratio is set to 100%.
New Connection Hyperterminal
File Edit View Call Transfer Help
Print echoCaptureNUMCAPSSCROLL9600-8-N-1Auto detectConnected 0:02:44
2. Set Config
-------------
Pump Motor Type: VaporTEK
VTEK-RS422 Type: Slave Device
HV Nozzle Speed: M1 = 2500 rpm
HV Nozzle Speed: M2 = 2500 rpm
Set M1 - Input performance (0...250RPM x10):120
Set M2 - Input performance (0...250RPM x10):120
Do you want to save it?[Y/N]: y
Config has been stored successfully
Pump Motor Type: VaporTEK
VTEK-RS422 Type: Slave Device
HV Nozzle Speed: M1 = 1200 rpm
HV Nozzle Speed: M2 = 1200 rpm
New Connection Hyperterminal
File Edit View Call Transfer Help
Print echoCaptureNUMCAPSSCROLL9600-8-N-1Auto detectConnected 0:02:44
3. Set Factory defaults
-----------------------
Are you sure? [Y/N]
Factory defaults has been set

Table of Contents

Other manuals for Veeder-Root VaporTEK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Veeder-Root VaporTEK and is the answer not in the manual?

Veeder-Root VaporTEK Specifications

General IconGeneral
BrandVeeder-Root
ModelVaporTEK
CategoryWater Pump
LanguageEnglish

Related product manuals