Solar Pump Controller Manual
27
F-07
Input signal action
mode selection
LED 0 digit: Free close-down restore
mode
0:After the disconnection, restore the
original order
1:After the disconnection, no restore
the original order
LED 10 digit: Ascend /descent
terminal control frequency setting
0: UP / DW terminals regulate after
running
1: Back to the last shutdown
instantaneous frequency, then UP /
DW regulate
2: First to [F-70], then UP / DW
regulate
LED 100 digit: keyboard
STOP/RESET
Button effective range selection
0: Only keyboard control effective
1: All control mode effective
LED 1000 digit: after fault reset,
terminal operation mode selection
0:Terminal control can restart directly
207H
F-08
Terminal operation
control mode
selection
0:Standard operation control
1:Double-line operation mode control
2:Trilinear operation mode control.
0
〇