Solar Pump Controller Manual
28
F-13
Filter coefficient of
DC bus voltage
06
3
20DH
F-14
periodic time
When ones of H47
value set for 2
0.0010.00S
0.03
20EH
F-15
Reference voltage
step length
increase when
lower than low limit
050V
5
20FH
F-16
Reference voltage
increase upper limit
when lower than
low limit
0100V
30
210H
F-17
Solar pump other
function selection
0000H1111H
0011
H
211H
F-18
H-35 parameters
pondage factor
0100.0%
50.0
%
212H
F-19
H-36 parameters
pondage factor
0100.0%
80.0
%
213H
F-20
H-37 parameters
pondage factor
0100.0%
90.0
%
214H
F-21
H-38 parameters
pondage factor
0100.0%
75.0
%
215H
F-22
Dry run protection
time
0.16000.0S
300.0
216H
F-23
Dry run protection
duration
0.16000.0S
1200.
0
217H
F-24 Acceleration time2
0.16500.0S
0.1S
F
F-25 Deceleration time2
0.1S
219H
F-26 Acceleration time3
15.0S
21AH
F-27 Deceleration time3
15.0S
21BH
F-28 Acceleration time4
218H
F-29 Deceleration time4
219H
F-30
Relay output
terminal
TA, TB, TC
0:Zero frequencystandby mode
1:Fault jump alarm1(fault
auto-restoration period alarm)
2:Fault jump alarm 2(fault
auto-restoration period no alarm
3:Frequency arrive detection
1
21EH