Loading...
GFV Cabinet, set Y home adjustments.
WORK CON
TENTS : Positioning the Y-Rail stop bracket, latch side.
Note:
STEPS: (1) Disconnect the Y
-Motor power connector as shown.
(2) Verify the X
-Rail assembly is set down against the Y-Rail stop on the latch side.
Move the X
-Rail up then down to verify.
(3) Close and latch the door. The door must be latched for this adjustment.
(4) Verify that the optic red light is below the reflector on tray 56/57 as shown.
(4a) If the amber LED on the forward looking optic is
illuminated, or flashing then the Y stop bracket must be lowered.
(4b) If the Y
-stop bracket needs to be lowered, lower it in increments of 0.100 inches until the amber LED is off.
(4c) Once the Y
-Stop bracket (latch side) is set, level the Y-Stop
bracket (hinge side) and tighten adjustment screws.
(4d) At this point the Y Stop brackets should be level with each other in relation to the X Rail assembly and the
adjustment screws for both sides should be tight.
.
Stupe 1
X
-
Rail Assembly
Remove
Step 4
There are two LEDS
(green, amber)
where indicated by
the red circle.
Green LED is on
constantly, the
amber LED comes on
Step 4a, Forward

Other manuals for Vendo VUE 30