GFV Cabinet, set Y home adjustment.
WORK CONTENTS : Checking position of the Y
Note: Once the Y Home Stop is adjusted the Y Home magnet must be tested and adjusted if required.
STEPS: (1) Adjust the Y Home magnet so that the top edge of th
bottom edge of the Y home sensor by 0.100" .
-Rail resting on the Y-Rail stops activate the "Sensor Status"
and verify the magnet is activating the sensor.
(3)If the Y Home sensor is active ('Yo" o is not filled in) g
(4)If the Y Home sensor is inactive adjust the Y Home magnet up 0.100 inches, reset the
Sensor Status by pressing key "4".
Repeat step 4 until the Y Home Sensor shows Active "Yo" ("o" not filled in),
"1" = exit /home
"2" = increase / advance
"3" = decrease / backup
"4" = enter / save
To Activate the Test Mode, Sensor Status:
1. Press the Mode button on the VMC board 2
times.
1a. Display should read "DAIGNOSTICS"
2. Press "key 2" until the "Test Mode"
appears in the display.
3. Press "key 4" to enter Test Mode menu.
4. Press "key 2" until the "Sensor Status"
appears.
5. Press "key 4" to enter Sensor Status.
To refresh Sensor Status press "key 4".
Sensor Status, "Yo", the "o" is the
indicator status:
? - Inactive (sensor did not detect magnet)
O - Active (sensor detected magnet)
Step 2