local legal guidelines. The technician instructs the operator about the operation, the maintenance and
the proceedings during possible malfunctions.
Do not place the machine in areas that are cleaned with water jets or steam.
It is required that a sufficiently fused wall outlet with proven grounding is present within 1½ meters
and an aerated washing machine faucet.
Besides the legal guidelines that a service technician has to meet, Veromatic International BV
moreover makes the following demands of a service technician:
1 The technician must be very well acquainted with the machine, through training by Veromatic
International B.V. or through similar training obtained elsewhere.
2 The technician must use the instructions, diagrams etc. that are applied to this type and
model.
3 The technician is well informed about the applicable guidelines for hygiene.
3.3 Installation location
The machine is intended only for use indoors, not outdoors. Place the machine in a frost-free location
where it is not exposed to moisture or excessive dust and cannot be sprayed with liquids. The machine
may not be used at an elevation over 2000 m.
The machine is only suited for use in household, office and light-industrial environments. The
machine is not suitable for professional kitchens where cleaning frequently occurs with water or in a
dusty environment. When placed in another environment, Veromatic International cannot guarantee
the correct operation or the safety of the
machine.
Do not place the machine in areas that are
cleaned with water jets or steam.
For correct operation the machine may not
be installed at an angle, but at a flat and
stable surface.
The ambient temperature has to be within
+10° to +32° Celsius for a correct operation
of the machine.
Make sure that the wall outlet and the
water valve remain free and easily
accessible after placement of the machine.
The main power switch is located on the
back of the machine. Make sure that this
also remains easily accessible.
Check to see that the electrical cable is not
damaged. A damaged electrical cable must
be replaced immediately!
Make sure there is enough open space
around the machine. Minimum needed
dimensions (in mm) see /3-2.
Place the machine as such that the highest surface of the machine is located at least 120 cm above the
floor surface.
If the unit is placed directly underneath a cupboard, allow a space of at least 150 mm. For a proper
operation of the machine it is necessary that cooling air can be supplied and discharged. For this
purpose many ventilation openings have been made in the machine. These openings may never be
covered.