59
EN
A transparent cup is used
(these are not always
detected!)
Use the glass function (see 5.1 point 6) or use an
opaque cup
Products not able
to select, error
brewer not in
position
The door is open.
The waste bin is not
placed.
The brewer is removed.
Re-)place brewer, waste bucket and close the
door.
Espresso/coffee is
much too light
and/or only a
fraction of the
volume.
1. Brewer is clogged.
2. Ground powder
(setting) is too fine.
1. Rinse the brewer, or additionally clean
thoroughly by removing/cleaning and cleaning
cycle (see 6.6.1 Weekly maintenance).
2. Ask your dealer to set the grinder more coarse.
Extended troubleshooting
Fault Cause
No lighting Ingredient canisters are empty
Wiring faulty
Door PCB faulty
No reaction on key press
Is pay system activated?
Does the LED react?
Is the wiring O.K.?
Is the motor / valve O.K.?
No or insufficient water Brewer clogged. Clean the brewer.
Grinding is too fine. Set to more coarse grind.
Is the inlet hose of the brewer connected?
Is the inlet hose coupling properly tightened and not
leaking?
Is the mixer clogged?
Is the water supply functioning?
Hose kinked? Enough pressure on the tap?
Water level correct in boiler? Switch the machine off,
drain the air break tank and switch on. Perform a
filling procedure.
Water system scaling?
Pay system does not work Is pay system activated?
Wiring O.K.?
Water temperature too low/high Too rapid succession of consumptions (max. 4 per
minute)?
Element O.K.?
Temperature protection (clixons) have switched off
the element? Switch the machine off, drain the air
break tank, reset the clixons of the boiler and switch
on. Perform a filling procedure. If problems persists,
replacement may be needed.