bands. On the 10/14 MHz bands, “FINE” [SELECT(µ-TUNE)] knob steps will
be used (1 step/click).
StP2: Activates the µ-TUNE system using “FINE” steps of the [SELECT(µ-TUNE)]
knob (1 step/click) on the 14 MHz and lower amateur bands.
Advice: If an optional RF µTuning Kit is not connected, this adjustment has no effect.
033 GENE MIC SCN
Function: Enables/disables scanning access via the microphone’s [UP]/[DWN] keys.
Available Values: On/OFF
Default Setting: On
034 GENE SCN RSM
Function: Selects the Scan Resume mode.
Available Values: CAr/5SEc
Default Setting: 5SEc
CAr: The scanner will hold until the signal disappears, then will resume after one
second.
5SEc: The scanner will hold for five seconds, then resume whether or not the other
station is still transmitting.
035 GENE FRQ ADJ
Function: Adjusts the reference oscillator.
Available Values: –25 ~ 0 ~ +25
Default Setting: 0
Connect a 50-Ohm dummy load and frequency counter to the antenna jack; adjust the
[CLAR/VFO-B] knob so that the frequency counter reading is same as the VFO
frequency while pressing the PTT switch.
Advice: Do not perform this Menu item unless you have a high-performance frequency
counter. Perform this Menu item after aging the transceiver and frequency counter
sufficiently (at least 30 minutes).