iPM 200 generator module
® Vetaphone March 2021 3401201GB
Page 10 of 52
Analog Input
Terminal number 21
4 to 20 mA or
0 to 10 VDC
Terminal number 22
Ground
Configurable for
4 to 20 mA
Voltage drop @ 20 mA
≤ 3.5 VDC
Configurable for
0 to 10 VDC
Input impedance
> 4.5 kOhm
Max voltage applied externally on terminals
24 V DC
Analog Output
Terminal number 23
4 to 20 mA or
0 to 10 VDC
Terminal number 24
Ground
RLOAD for 4 to 20 mA
≤ 500 Ohm
RLOAD for 0 to 10 VDC
≥ 1.2 kOhm
iPM200 (X4, Customer Relay output)
Terminal number 1
Relay K1- Common
Terminal number 2
Relay K2- Common
Terminal number 3
Relay K1- Normally
Closed
Terminal number 4
Relay K2- Normally
Closed
Terminal number 5
Relay K1- Normally
Open
Terminal number 6
Relay K2- Normally
Open
Contacts max load
500 mA @ 125 VAC
1.5 A @ 30 VDC
iPM200 (X5,Station I/O)
Terminal number 1, 2, 24, 26
Supply output
Max. output supply voltage
24 V DC
Max. output current
400 mA (total)
Terminal number 15
Logic ground
Terminal number 25
Supply output ground
Terminal number 27, 28
Interlock 1
For interlock use only potential free contacts