03. Use / to select "P10".
04. OK to confirm
05. Use / to select access code 2
for parameter level 2.
06. OK to confirm
"PL:2" is shown on the addi-
tional display
is shown in the upper dis-
play area
07. MODE to confirm
08. Use / to select "P27".
09. OK to confirm
10. Use / to select "On".
11. OK to confirm
12. MODE to exit the parameter level.
If communication between the control
unit and the extension is working,
flash simultaneously.
If communication between the control
unit and the extension is faulty,
flash alternately. Fault "CC" is
shown.
Repeat the steps and set value
"OFF" in "P27". Then repeat the
steps once more and select value
"On" again.
The functions of the external extension
are set in "P40" to "P49".
Installation and service instruc-
tions
External extension
Switching off DHW heating
If the boiler is to be operated without
DHW heating (conventional gas boiler):
Switch off the function at the control
unit.
01. Hold down MODE and simulta-
neously for approx. 5 s.
"SEt" and flash
"PL:1" is shown on the addi-
tional display
is shown in the upper display
area
02. Press MODE.
03. Use / to select "P10".
04. OK to confirm
05. Use / to select access code 2
for parameter level 2.
06. OK to confirm
"PL:2" is shown on the addi-
tional display
is shown in the upper dis-
play area
07. MODE to confirm
08. Use / to select "P13".
09. OK to confirm
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5837146
Service

Table of Contents

Other manuals for Viessmann Vitopend 100-W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitopend 100-W and is the answer not in the manual?

Viessmann Vitopend 100-W Specifications

General IconGeneral
Fuel TypeGas
Max. Water Temperature85 °C
TypeCondensing Boiler
Gas TypeNatural gas / LPG
EfficiencyUp to 98%

Related product manuals