2.4Selection of collector types
Vitosol 100
c
18
VITOSOL
Pitched roofs  roof integration
Design information regarding installation surfaces
H We can recommend roof integration only
for roofs with roof tile cover and a
gradient of at least 25º, and with tile
cover, whose tiles have a dimension "c"
of at least 65mm.
Discuss the installation with a roofing
contractor first, if flat tiles are used,
such as Tegalit or similar.
H On new buildings, leave the
corresponding area of normal roof
battens uncovered (see drawing).
H Account for at least 3rows of tiles on
the roof ridge to ensure adequate
ventilation below the roof.
Collector type
s/w 2.5 5 DI
Dimension mm a b a b
Vertical installation 3000 2160 + 1160
*1
2800 3300
Horizontal installation 1500 3410 + 2410
*1
 
*1
Add this value for every additional collector.