2.4Selection of collector types
Vitosol 100
CD
BA
19
VITOSOL
H Type s/w2.5
A Collector
B Covering frame
C Additional battens
D V−ledge to support the flashing
Water drain
Collector
amm
Type s
Type w
2385
1138
H Type 5 DI
A Collector
B Covering frame
C Additional batten
D Lead flashing
→Water drain
Note
The battens supplied are statically designed
for the following snow load zones:
H Snow load zone 1,
up to 500 m above sea level
H Snow load zone 2,
up to 400 m above sea level
H Snow load zone 3,
up to 300 m above sea level
Fit an additional batten (on−site) at greater
terrain heights in the respective snow
load zones, as well as in snow load zone 4.
Maintain a clearance between individual
modules of 2 to 3 rows of tiles, if several
collectors are fitted.
(Make all water connections on site.)
5822135 GB