34
Diagnostics
Service Tests (continued)
202 Default Defrost Operation
Press the “UR” keypad or “LR” keypad to toggle defrost operation from normal adaptive defrost (off position)
to minimum time between defrosts (on position).
203 Show Temperature Set points–Disregard this Test (unit will not display actual-temperature only set
temperature).
211 Fresh Food Temperature Offsets
Press the “UR” keypad or “LR” keypad to toggle calibration of fresh food temperature plus or minus in 1°F
increments up to 6°F.
Note: Temperature will read in fahrenheit regardless of what current temperature scale is being used.
212 Freezer Temperature Offsets
Press the “UR” keypad or “LR” keypad to toggle calibration of freezer temperature plus or minus 1°F in
increments up to 6°F.
Note: Temperature will read in fahrenheit regardless of what current temperature scale is being used.
Press either
button to
cycle normal
adaptive defrost (OFF)
to minimum
time between
defrosts (ON)
Press either
button to
toggle through
test cycles
202 OFF
Press either
button to change
calibration of fresh
food temperature
plus or minus in
1˚ increments
Press either
button to
toggle through
test cycles
211 1
Press either
button to change
calibration of freezer
temperature plus
or minus in
1˚ increments
Press either
button to
toggle through
test cycles
212 1