3.6) Reference technical standards
The stairlift complies with the following norms:
- Directive 2004/108/EEC “Electromagnetic Compatibility”
- Directive 2006/95/EEC “Low Voltage”
- Directive 2006/42/EEC “Machinery Directive”
4) TECHNICAL SPECIFICATIONS
- Drive system
Worm gear reduction unit Ratio 1/40
- Performance levels
Travel direction Forward/backward
Speed (up/down) 0.15 m/s
Capacity 1 person
Gradient from 0° to 50°
Working load 250 kg up to 45°
- 300 kg for platform with P ≤ 770 and gradient up to 45°
- 250 kg for platform with P > 770 and gradient up to 45°
- 200 kg with gradient between 45° and 50°
- Duty cycles
Normal service 20 min/hour max.
- Ambient conditions for outdoor stairlifts
Temperature From -10°C to +60°C (suggested and recommen-
ded)
Humidity maximum 70% (use in bathrooms and swimming-pools is
not permitted) (suggested and recommended)
- Electrical system
Drive motor 24 V d.c. 1 kW
Power absorption 40 A
- Controls
Up/down control button “Dead man” type
Emergency stop button with detent
Key-switch