Manual VIPA System 300V Chapter 6 Deployment CPU 31x with TCP/IP
HB130E - CPU - Rev. 11/50 6-45
1
6
5
73
2
4
You can use this dialog window to send a message to a specific host.
Input fields
Remote Host IP-address of the station where the data must be saved.
Remote Port port address of the remote station.
Local Port port address of own (local) station. To simplify matters
you can specify the same port address for remote and
local.
Time (10mSec) definable interval for cyclic write operations. The minimum
timer value for cyclic writes is 5.
Tick-box
UDP this tick mark selects unsecured communications. No
virtual connections are used by unsecured
communication links. In this manner you can only display
UDP messages.
Buttons
Connect the connection is established and prepared for the write
operation.
Send this data entered into the ASCII field is transferred to the CP
via the connection that was established by means of
Connect.
Send tab
[1] port data
[2] establish a connection
[3] transfer data via the
connection
[4] list of transmitted
messages
[5] information bar for the
connection status
[6] clear the list of messages
[7] ASCII-text that must be
transferred to the CP