2 SECTION 1: INSTALLATION
EPI800 Manual.doc EPI 800 MANUAL 2001 Vision Microsystems Inc.
1.2 INDICATOR MOUNTING AND CONNECTION
Mounting:
Indicators are mounted to the panel from the backside. Four mounting
screws are provided for this purpose. Do not use longer screws or
damage to the instrument will result. The supplied screws will
accommodate panel thickness from 0.062 to 0.050 inches. If a panel
thickness of other than this is required, then determine the difference in
thickness and procure new screw length accordingly. Test your new
screw lengths by finger tightening them into the panel and indicator. The
screws should tighten against the panel only and should not 'bottom out'
in the indicator. Be careful not to cross thread the screws or the indicator
bezel will be permanently damaged. The cut-out and mounting space
requirement information is provided in 'FIGURE 1: EPI 800 IND. &
SWITCH MOUNTING'.
If you are uncomfortable with laying out the hole patterns, check with the
factory for availability of indicator cutout templates.
Connection:
Indicators are connected to the DPU by plugging them into any desired
connector on the Display Cable. Be careful not to press on indicator
glass surface while inserting connector.