36 SECTION 2: OPERATION
EPI800 Manual.doc EPI 800 MANUAL 2001 Vision Microsystems Inc.
2.16 IO INTERFACE BOARD OPERATION
The IO Interface Board Annunciator operation is automatic. When an
alert condition initially happens, the corresponding warning
annunciator lamp (opt.) will begin to flash and a pulsing audio side
tone output is generated. This flashing and audio will continue for a
short time period, after which the flashing will change to a steady 'on'
condition and the audio will extinguish.
If you have connected an optional 'Acknowledge Switch’, the flashing
and audio can be terminated by pressing the switch for a short period
of time. Continuing to hold the switch down will generate a ‘SELF
TEST’ function that tests the annunciator lights and audio output.
The following is a list of annunciated alerts:
OIL TEMPERATURE - oil temp has been exceeded
OIL PRESSURE - oil pressure is too low
FUEL PRESSURE - fuel pressure is too low
FUEL COMPUTER TOTAL - computer fuel total is too low
LEFT TANK - left tank fuel level is too low
RIGHT TANK - right tank fuel level is too low
CENTER TANK - center tank fuel level is too low
VOLTAGE - voltage at sensing point is too low
AMPS - amperage discharge has been detected
PEAK EGT - peak egt has been reached in 'peak mode'
CHT - cylinder head(s) are too hot or shocked cooled
TIMER - count down time has expired