EasyManuals Logo

vision microsystems EPI 800 User Manual

Default Icon
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
SECTION 1: INSTALLATION 5
EPI800 Manual.doc EPI 800 MANUAL 2001 Vision Microsystems Inc.
1.5 MANIFOLD PRES. TRANSDUCER INST.
The transducer is mounted in a temperature controlled environment in
the cabin area utilizing the 10-32 UNF-2B tapped threads. Install the
supplied transducer snubber (hex brass part) to the transducer using
a pipe thread sealant and tighten to prevent leakage. Fabricate an
aircraft grade hose assembly and connect between the snubber (1/8
female NPT) and engine manifold pressure port (see your engine
manual for this location and thread requirements).
Connect to the DPU harness as shown in
APPENDIX B: DPU P1 Connector Harness Fabrication’ using the
supplied terminals.
IMPORTANT NOTES:
DO NOT: remove or drill the snubber inner silver filter.
DO NOT: modify, connect to, or break off the small black
plastic hose nipples on the sensor body.
DO NOT: mount the transducer near extremely hot areas such
as heater ducts, etc.
DO NOT: mount the transducer where corrosive or conductive
fluids may contact it during operation or maintenance.
DO NOT: mount the transducer in the engine compartment.
DO NOT: mount the transducer lower than the engine manifold
access port, or accumulated fuel/oil in the hose will not run
back into the engine and may cause sluggish performance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the vision microsystems EPI 800 and is the answer not in the manual?

vision microsystems EPI 800 Specifications

General IconGeneral
Brandvision microsystems
ModelEPI 800
CategoryControl Systems
LanguageEnglish